Customize Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorized as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customized advertisements based on the pages you visited previously and to analyze the effectiveness of the ad campaigns.

No cookies to display.

LPG Center – designed for cold climate testing

LPG Center
Workshops and offices

The main workshop and office building providies excellent facilities also for bigger groups. The large workshop is prepared to fit all kinds of vehicles from passenger cars to trucks.

Cold chambers next to the workshop ensure chilling temperatures down to -45°C.

Whether testing combustion, electric or hydrogen vehicles we can provide the required charging and fueling services through our partners.

Offices

  • Overall size 461 m²
  • 3 small offices for 5 persons (13 m²)
  • 3 medium size offices for 7 persons (18 m²)
  • 4 large offices for 10 persons (32 m²)
  • Meeting room for 15-20 persons (31 m²) – optionally up to 100 m² / 60 persons
  • Dining room and kitchen
  • Toilets, social room
  • WiFi

Workshop

  • Overall size 1.080 m²
  • 3 different size workshops (can be connected)
  • Capacity 20-30 passenger cars / 5-10 trucks
  • 4 drive-through workshops
  • 3 car lifts
  • 1 service pit
  • Car wash street

Cold chambers

5 large chambers

  • Interior measures: height 3.18 m / width 2.6 m / length 8.8 m
  • Min. temperature inside the chamber -45°C

3 medium chambers

  • Interior measures: height 2.6 m / width 2.4 m / length 6.8 m
  • Min. temperature inside the chamber -30°C

Fuel station

The proving ground is equipped with a fuel station. Special fuel types also can be arranged upon request.

 

Three standard fuels always available

  • 95E10 95-octane with 10% bio-ethanol, EN228/2012
  • 98E5 98-octane with 5% bio-ethanol, EN 228/2012
  • Diesel Arctic -29/-38C EN 590

EV-charging stations

The proving ground is equipped with top tier EV-charging devices. They can be used easily with our RFID-card.

High power charging

  • 2x240kW 1000V CCS2
  • 2x150kW 400V CCS2

Regular charging

  • 1x50kW DC, CCS2 or CHAdeMo
  • 3x22kW AC Type2

Arctic research center – The perfect HQ for durability testing